TECHNICAL DATA (50Hz)
GENSET MODEL
GFS-8
GFS-10
GFS-12
GFS-15
GFS-20
DIESEL ENGINE MODEL
YSAD380
YD480
YD485
YSD490Q
Y4100
Engine Characters
Water-cooled, in line, 4-cycle, direct injection, 1500rpm
Bore/Stroke (mm)
80/85
80/90
85/90
90/100
100/115
Rated output (KW)
10
13.2
15
21
27
Fuel Consumption (g/kw.hr)
<247
<250.2
<248.9
<247.5
<237
Lube Consumption (g/kw.hr)
<2.72
Compression ratio
18
Starting
Electric (12V)
ALTERNATOR MODEL
SLG164B
SLG164C
SLG164D
SLG184E
SLG184F
Rated power (KW)
8
10.8
12.8
15
22
Voltage (V)
230/400
230/400
230/400
230/400
230/400
Current(A)
14.4
18
21.6
27
36
Frequency (Hz)
50
Power factor (cos)
0.8
Dimensions (LxWxH) mm
1660x800x950
1660x800x950
1830x880x950
1830x880x950
2000x900x1040
Net Weight (kg)
650
700
750
800
900

 

 


Maxi Range | SFS Series: Single-Phase Soundproof Diesel Generator

TECHNICAL DATA (50Hz)
GENSET MODEL
GFS-8
GFS-10
GFS-12
GFS-15
GFS-20
DIESEL ENGINE MODEL
YSAD380
YD480
YD485
YSD490Q
Y4100
Engine Characters
Water-cooled, in line, 4-cycle, direct injection, 1500rpm
Bore/Stroke (mm)
80/85
80/90
85/90
90/100
100/115
Rated output (KW)
10
13.2
15
21
27
Fuel Consumption (g/kw.hr)
<247
<250.2
<248.9
<247.5
<237
Lube Consumption (g/kw.hr)
<2.72
Compression ratio
18
Starting
Electric (12V)
ALTERNATOR MODEL
SLG164B
SLG164C
SLG164D
SLG184E
SLG184F
Rated power (KW)
8.4
11
13
16.6
20
Voltage (V)
115/230
115/230
115/230
115/230
115/230
Current(A)
69.5/34.8
87/43.5
104.4/52.2
130.4/65.2
174/87
Frequency (Hz)
50
Power factor (cos)
1
Dimensions (LxWxH) mm
1660x800x950
1660x800x950
1830x880x950
1830x880x950
2000x900x1040
Net Weight (kg)
650
700
750
800
900

 


 

SFS Series: Single-Phase Soundproof Diesel Generator
Rating Definitions
Continuous Power Model D with no Suffix
These ratings are applicable for supplying continuous electrical power (at variable load)
in lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power Model D with Suffix (S)
These ratings are applicable for supplying continuous electrical power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. The
alternator on this model is peak continuous rated (as defined in ISO8528-3) at 27°C

Maxi Range | SFS Series: Single-Phase Soundproof Diesel Generator

AIR-COOLED GENERATOR SETS
WATER COOLED GENERATOR SETS
GENSET
Continuous model
D20
D30
D40
D48
D24W
D40W
D48W
D75W
D100W
D120W
MODEL
Standby model
D22S
D33S
D44S
D53S
D24WS
D40WS
D48WS
D75WS
D100WS
D120WS
Continuous output (KW/KVA)
20/25
30/38
40/50
48/60
25/31.3
40/50
48/60
75/94
100/120
120/150
Standby output (KW/KVA)
22/28
33/41
44/55
52.8/66
27.5/34.3
44/55
52.8/66
82/102.5
110/132
132/165
TECHNICAL DATA
DIESEL ENGINE MODEL
F3L912
F4L912
F6L912
F6L913
D226B-3D
TD226B-3D
TD226B-4D
TD226B-6D
TBD226B-6D
TBD226B-6D/13023811
Engine Characters
Vertical type, 4-stroke, air-cooled,
Water-cooled, in-line, 4-stroke, humid cylinder liner, direct injection
direct injection, 1500 rpm
Constant output (KW)
24
32
48
51
30
45
60
90
120
132
Standby output (KW)
26
35
52
54
33
49.5
66
99
132
145.2
Aspiration
Naturally
Naturally
Turbo charged
Turbo charged
Bore (mm)x Stroke (mm)
100X120
105X120
Cubic Capacity (Liters)
2.8
3.8
5.7
6.1
3.12
4.16
6.23
Compression Ratio
17:1
18:1
Speed characteristics
The speed stability bandwidth <+0.25%, the steady governing rate <1%
Fuel Consumption (g/KW.h)
<215
<218
<221
<234
<208
<205
Lube Consumption (prime)
<1.36g/kW.h
<1.45g/kW.h
ALTERNATOR MODEL
SLG184F
SLG184H
SLG224D
SLG224E
SLG184G
SLG224D
SLG224E
SLG274C
SLG274E
SLG274F
Continuous Output (KW/KVA)
22/28
30/38
40/50
48/60
25/31.3
40/50
48/60
80/100
112/140
128/160
Power Efficiency
90%
90%
90%
90%
91%
90.6%
91.2 %
90.1 %
90%
90%
Voltage Regulation
+/- 1.0 % with 4 % engine governing
Waveform Distortion
No load <1.5 % and non-disttorting balanced linear load <5 %
THF/TIF
<2% / <50
OPEN TYPE
DIMENSIONS AND WEIGHTS
Genet Cont. MODEL
D20
D30
D40
D48
D24W
D40W
D48W
D75W
D100W
D120W
Length: mm
1650
1880
2000
2085
168
168
220
245
250
260
Width: mm
820
820
820
1260
70
70
70
90
90
90
Height: mm
1200
1240
1240
1200
150
150
150
170
185
185
Net Weight: kg
950
975
995
1550
650
660
800
1300
1450
1600



 


 


DEUTZ RANGE OF SOUND-PROOF GENERATOR SETS D20/S-D48/S & D48W/S-D120W/S
Rating Definitions
Continuous Power Model D with no Suffix
These ratings are applicable for supplying continuous electrical power (at variable load)
in lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power Model D with Suffix (S)
These ratings are applicable for supplying continuous electrical power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. The
alternator on this model is peak continuous rated (as defined in ISO8528-3) at 27°C

Maxi Range | DEUTZ RANGE OF SOUND-PROOF GENERATOR SETS D20/S-D48/S & D48W/S-D120W/S

SOUNDPROOF GENSET CHARACTERISTICS
HIGHLY CORROSION RESISTANT CONSTRUCTION
* Body made from special treated steel sheet.
* Stainless steel or cast aluminium locks and hinges.
* Zing plated or stainless steel fasteners.
* 2.5mm thick Sheet treated by grit blast Sa 2
* Two pack of epoxy paint system.
* Full length extra wide doors on each side. * Control panel viewing window to easily view status of generating set.
* Doors top hung and supported by gas struts. * Emergency stop button mounted externally.
* Top hinged doors provide a shelter when open. * Cooling fan and battery charging alternator fully guarded.
* Exhaust silencing system totally enclosed for operator safety.
DIMENSIONS AND WEIGHTS
Sound-proof Genset Rating Power 400V/50HZ Width: mm Height: mm Net Weight: kg
Cont. Model kW kVA
D20/S 20 25 870 1400 1050
D30/S 30 38 870 1440 1075
D40/S 40 50 870 1400 1050
D48/S 48 60 1310 1400 1650
D24W/S 24 30 700 1500 950
D40W/S 40 50 700 1500 1050
D48W/S 48 60 700 1500 1150
D75W/S 75 94 900 1700 1300
D100W/S 100 120 900 1850 1450
D120W/S 120 150 900 1850 1600
 


 


PERKINS RANGE OF STANDARD GENERATOR SETS P30 - P56
Rating Definitions
Continuous Power Model P with no Suffix
These ratings are applicable for supplying continuous electrical power (at variable load)
in lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power Model P with Suffix (S)
These ratings are applicable for supplying continuous electrical power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. The
alternator on this model is peak continuous rated (as defined in ISO8528-3) at 27°C

Maxi Range | PERKINS RANGE OF STANDARD GENERATOR SETS P30 - P56

MAIN SPECIFICATIONS OF GENERATOR SETS
GENSET
Continuous model
P30
P34
P36
P40
P48
P56
MODEL
Standby model
P33S
P37S
P40S
P44S
P52S
P61S
Continuous output (KW/KVA) 30/38 34/42 36/45 40/50 48/60 56/70
Standby output (KW/KVA) 33/41 37/46 40/50 44/55 52/65 61/76
TECHNICAL DATA
DIESEL ENGINE MODEL
1004G
1004G
1004G
1004TG
1004TG
1004TG
Engine Characters
Water-cooled, in line, 4-cylinders, 4-stroke, direct injection, Dry cylinder liner, 1500rpm
Constant Output (KW)
40
65.7
Standby Output (KW)
44
72.3
Aspiration
Natural
Turbochargered
Bore (mm) x Stroke (mm)
100 x 127
Cubic Capacity (Liters)
3.99
3.99
Piston Speed (m/s)
6.35
6.35
Compression Ration
16.0:1
16.0:1
Stability bandwidth
<+-0.8%
<+-0.8%
Steady governing rate
<5%
<5%
Acoustic Pressure
<91.2dBA (At full load, 1m distance)
<91.2dBA (At full load, 1m distance
Exhaust Temperature:°C
600
561
Exhaust Back PRESSURE
5KPa
6KPa
Air induction System
Dry element type with back pressure warning indication
Lube Temperature / Capacity
125°C/8.1L(Max.)
BMEP: kPA (Prime power)
882
1369
Heat Rejection to Exhaust
35.7 kW/min
53.4kW/min
Heat Rejection to Cooling
38 kW/min
43 kW/min
Cooling System Volume
21L
22.2L
Cooling Air Flow
55 m3/min
100 m3/min
Combustion Air Flow
2.64 m3/min
4.52 m3/min
Exhaust Gas Flow
7.54 m3/min
13.1 m3/min
Min. Fuel Consumption
<210 g/kW.h
<205 g/kW.h
ALTERNATOR MODEL SLG184H SLG224C SLG224D SLG224D SLG224E SLG224F
Continuous Output (KW/KVA) 30/37.5 34/42.5 40/50 40/50 48/60 58/72.5
Power Efficiency 86.3% 87% 88.2% 88.2% 88.6% 90%
Voltage Regulation +/- 1.0% with 4% engine governing
Waveform Distortion No load < 1.5 % and non-disstorting balanced linear load <5%
THF / TIF <2%/<50
DIMENSIONS AND WEIGHTS
Genet Cont. MODEL P30 P34 P36 P40 P48 P56
Length: mm 2100 2100 2130 2130 2130 2130
Width: mm 710 710 710 710 710 710
Height: mm 1260 1260 1260 1340 1340 1340
Net Weight: kg 1040 1050 1080 1080 1100 1400
 


 


PERKINS RANGE OF STANDARD GENERATOR SETS P68 - P108
Rating Definitions
Continuous Power Model P with no Suffix
These ratings are applicable for supplying continuous electrical power (at variable load)
in lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power Model P with Suffix (S)
These ratings are applicable for supplying continuous electrical power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. The
alternator on this model is peak continuous rated (as defined in ISO8528-3) at 27°C

PERKINS RANGE OF STANDARD GENERATOR SETS P68 - P108

MAIN SPECIFICATIONS OF GENERATOR SETS
GENSET Continuous model P68 P72 P80 P91 P108
MODEL Standby model P75S P80S P88S P100S P120S
Continuous output (KW/KVA) 68/85 72/90 80/100 91/114 108/135
Standby output (KW/KVA) 75/94 80/100 88/110 100/125 120/150
TECHNICAL DATA
DIESEL ENGINE MODEL 1006TG1A 1006TG1A 1006TG2A 1006TAG 1006TAG
Engine Characters Water-cooled, in line, 4-cylinders, 4-stroke, direct injection, Dry cylinder liner, 1500rpm
Constant Output (KW) 84.3 92.3 121
Standby Output (KW) 92.7 102 134
Aspiration Turbocharged Turbocharged Turbochargered and aftercooled
Bore (mm) x Stroke (mm) 100x127 100x127 100x127
Cubic Capacity (Liters) 5.99 5.99 5.99
Piston Speed (m/s) 6.35 6.35 6.35
Compression Ration 16:1 16:1 17:1
Stability bandwidth <+-0.8% <+-0.8% <+-0.25%
Steady governing rate <5% <5% <1%
Acoustic Pressure <92.1dBA (At full load, 1m distance) <94.3dBA <94.9dBA
Exhaust Temperature:°C 545 550 571
Exhaust Back PRESSURE 6KPa 6KPa 6KPa
Air induction System Dry element type with back pressure warning indication
Lube Temperature / Capacity 125°C/16.1L(Max.) 125°C/19L(Max.)
BMEP: kPA (Prime power) 1283 1404 1964
Heat Rejection to Exhaust 59.1 kW/min 66.5 kW/min 115 kW/min
Heat Rejection to Cooling 56 kW/min 63kW/min 65.5 kW/min
Cooling System Volume 27.7L 27.7L 37.2L
Cooling Air Flow 135 m3/min 135 m3/min 154 m3/min
Combustion Air Flow 5.74 m3/min 5.74 m3/min 8.38 m3/min
Exhaust Gas Flow 15.56 m3/min 16.24 m3/min 24.14 m3/min
Min. Fuel Consumption <205g/kW.h
ALTERNATOR MODEL SLG224G SLG274C SLG274C SLG274D SLG274E
Continuous Output (KW/KVA) 68/85 80/100 80/100 91/114 112/140
Power Efficiency 90.2% 90.4% 90.4% 90.8% 91.7%
Voltage Regulation +/- 1.0% with 4% engine governing
Waveform Distortion No load < 1.5 % and non-disstorting balanced linear load <5%
THF / TIF <2%/<50
DIMENSIONS AND WEIGHTS
Genet Cont. MODEL P68 P72 P80 P91 P108
Length: mm 2480 2480 2480 2580 2580
Width: mm 710 710 710 800 800
Height: mm 1480 1480 1480 1480 1480
Net Weight: kg 1440 1490 1500 1520 1600
 


 

PERKINS RANGE OF SOUND-PROOF GENERATOR SETS P30/S-P108/S

SOUNDPROOF GENSET CHARACTERISTICS
HIGHLY CORROSION RESISTANT CONSTRUCTION
* Body made from special treated steel sheet.
* Stainless steel or cast aluminium locks and hinges.
* Zing plated or stainless steel fasteners.
* 2.5mm thick Sheet treated by grit blast Sa 2½
* Two pack of epoxy paint system.
EXCELLENT ACCESS FOR MAINTENANCE SECURITY AND SAFETY
* Full length extra wide doors on each side. * Control panel viewing window to easily view status of generating set.
* Doors top hung and supported by gas struts. * Emergency stop button mounted externally.
* Top hinged doors provide a shelter when open. * Cooling fan and battery charging alternator fully guarded.
* Lube oil and cooling water drains piped to exterior of the canopy. * Exhaust silencing system totally enclosed for operator safety.
DIMENSIONS AND WEIGHTS
Sound-proof Genset Rating Power 400V/50HZ Length: mm Width: mm Height: mm Net Weight: kg
Cont. Model kW kVA
P30/S
30
38
2150
880
1230
1250
P34/S
34
42
2150
880
1230
1260
P36/S
36
45
2150
880
1230
1300
P40/S
40
50
2250
1060
1230
1400
P48/S
48
60
2250
1060
1230
1460
P56/S
56
70
2550
1060
1230
1760
P68/S
68
85
2550
1060
1260
2120
P72/S
72
90
2550
1060
1260
2140
P80/S
80
100
2550
1060
1260
2150
P91/S
91
114
2650
1060
1260
2170
P108/S
108
135
2650
1060
1260
2200
 


 


CUMMINS RANGE OF STANDARD GENERATOR SETS C20-C104
Rating Definitions
Continuous Power Model C with no Suffix
These ratings are applicable for supplying continuous electrical power (at variable load)
in lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power Model C with Suffix (S)
These ratings are applicable for supplying continuous electrical power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. The
alternator on this model is peak continuous rated (as defined in ISO8528-3) at 27°C

CUMMINS RANGE OF STANDARD GENERATOR SETS C20-C104

MAIN SPECIFICATIONS OF GENERATOR SETS
GENSET Continuous model C20 C30 C45 C68 C77 C91 C104
MODEL Standby model C22S C33S C50S C75S C85S C100S C114S
Continuous output (KW/KVA) 20/25 30/37.5 45/56 68/85 77/96 91/114 104/130
Standby output (KW/KVA) 22/27.5 33/41.25 50/63 75/94 85/106 100/125 114/143
TECHNICAL DATA
DIESEL ENGINE MODEL 4B3.9-G2 4BT3.9-G2 4BTA3.9-G2 6BT5.9-G2 6BT5.9-G2 6BTA5.9-G2 6BTAA5.9-G2
Engine Characters Water-cooled, in line, 4-stroke, direct injection, Wet cylinder liner, 1500rpm
Constant Output (KW) 24 36 50 92 92 110 120
Standby Output (KW) 27 40 55 100 100 120 132
Aspiration Naturally Turbo Turbo & Aftercooled Turbo Turbo & Aftercooled
Bore (mm) x Stroke (mm) 102 x 120
Cubic Capacity (Liters) 3.91 5.9
Piston Speed (m/s)  
Compression Ratio 16.5:1 17.5:1
Cooling System Volume (L) 8 11 31 17
Max. Water Temperature 100°C
Speed characteristics The speed stability bandwidth <+0.25%. The steady governing rate <1%
Fuel Consumption <215g/kW.h <220g/kW.h
Lube Consumption (prime) <1.36g/kW.h
Radiated Heat to Ambient (KWm) 6 6 8 14 N/A N/A
Heat Rejection to coolant (KWm) 27 27 29 62 N/A N/A
Heat Rejection to Exhaust (KWm) 38 38 41 69 N/A N/A
Fan Cooling Air Flow (m3/h) 6790 7470
Intake Air Flow (l/s) 52 52 52 94 N/A N/A
Exhaust Gas Flow (m3/h) 572 601 612 840 1020 1302 1352
Exhaust Temperature (°C) 480 492 502 510 576 524 541
Exhaust Back Pressure 10kPa(Maximum)
ALTERNATOR MODEL SLG184F SLG184H SLG224E SLG224G SLG274C SLG274D SLG274E
Continuous Output (KW/KVA) 22/275 30/37.5 48/60 68/85 80/100 91/114 112/140
Power Efficiency 81% 90% 88.6% 90.2 % 90.4 % 90.8 % 91.7 %
Voltage Regulation +- 1.0 % with 4 % engine governing
Waveform Distortion No load < 1.5% and non-disttorting balanced linear load < 5 %
THF/TIF <2% / <50
Fan Cooling Air Flow (l/s) 216 514
DIMENSIONS AND WEIGHTS
Genet Cont. MODEL C20 C30 C45 C68 C77 C91 C104
Length: mm 1610 1610 1630 2070 2190 2330 2330
Width: mm 650 650 650 750 750 750 750
Height: mm 1340 1340 1460 1460 1460 1460 1460
Net Weight: kg 950 1050 1110 1370 1400 1500 1500
 


 


CUMMINS RANGE OF STANDARD GENERATOR SETS C20-C104
Rating Definitions
Continuous Power Model C with no Suffix
These ratings are applicable for supplying continuous electrical power (at variable load)
in lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power Model C with Suffix (S)
These ratings are applicable for supplying continuous electrical power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. The
alternator on this model is peak continuous rated (as defined in ISO8528-3) at 27°C

CUMMINS RANGE OF STANDARD GENERATOR SETS C20-C104

MAIN SPECIFICATIONS OF GENERATOR SETS
GENSET Continuous model C140 C160 C200 C250 C280
MODEL Standby Model C160S C176S C220S C275S C310S
Continuous output (KW/KVA) 140/175 160/200 200/250 250/313 280/350
Standby output (KW/KVA) 160/200 176/220 220/275 275/344 310/388
TECHNICAL DATA
DIESEL ENGINE MODEL 6CTA8.3-G2 6CTAA8.3-G2 NTA855-G1 NTA855-G2 NTA855-G4
Engine Characters Water-cooled, in line, 4-stroke, direct injection, Wet cylinder liner, 1500rpm
Constant Output (KW) 163 183 240 283 317
Standby Output (KW) 180 205 265 321 351
Aspiration Turbocharged and Aftercooler
Bore (mm) x Stroke (mm) 114x135 140x152
Cubic Capacity (Liters) 8.3 14
Piston Speed (m/s) 6.75 7.6
Compression Ratio 17.01:1 15:1
Cooling System Volume (L) 12.3 51
Max. Water Temperature 100°C
Speed characteristics The speed stability bandwidth < +- 0.25%. The steady governing rate <1%
Fuel Consumption 210g/kW.h
Lube Consumption (prime) <1.36g/kW.h
Radiated Heat to Ambient (KWm) 24 42 46
Heat Rejection to coolant (KWm) 88 167 187
Heat Rejection to Exhaust (KWm) 127 208 212
Fan Cooling Air Flow (m3/h) 19980 29380 29448
Intake Air Flow (l/s) 163 375 408
Exhaust Gas Flow (m3/h) 1850 3550 4060
Exhaust Temperature (°C) 638 4850C 5410C
Exhaust Back Pressure 10kPa(Maximum)
ALTERNATOR MODEL
SLG274G
SLG274H
SLG314C
SLG314E
SLG314F
Continuous Output (KW/KVA) 140/175 160/200 200/250 260/325 304/380
Power Efficiency 92.5% 93.3% 92% 93% 92.6%
Voltage Regulation +- 1.0% with 4% engine governing
Waveform Distortion No load < 1.5% and non-disttorting balanced linear load <5%
THF/TIF <2% / <50
Fan Cooling Air Flow (l/s) 514 486
DIMENSIONS AND WEIGHTS
Genet Cont. MODEL
C140
C160
C200
C250
C280
Length: mm
2500
3090
3550
3550
3620
Width: mm
820
1120
1120
1120
1120
Height: mm
1650
1600
1600
1600
1600
Net Weight: kg
2000
2800
3200
3400
3550
 


 


CUMMINS RANGE OF STANDARD GENERATOR SETS C300-C800
Rating Definitions
Continuous Power Model C with no Suffix
These ratings are applicable for supplying continuous electrical power (at variable load)
in lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Power Model C with Suffix (S)
These ratings are applicable for supplying continuous electrical power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. The
alternator on this model is peak continuous rated (as defined in ISO8528-3) at 27°C

CUMMINS RANGE OF STANDARD GENERATOR SETS C300-C800

MAIN SPECIFICATIONS OF GENERATOR SETS
GENSET
Continuous model
C300
C360
C400
C500
C600
C800
MODEL Standby model C330S C400S C440S C565S C670S C900S
Continuous output (KW/KVA) 300/375 360/450 400/500 512/640 600/750 800/1000
Standby output (KW/KVA) 330/413 400/500 440/550 565/706 670/838 900/1125
TECHNICAL DATA
DIESEL ENGINE MODEL KTA19-G2 KTA19-G3 KTA19-G4 KTA38-G KTA38-G2 KTA38-G5
Engine Characters Water-cooled, in line, 4-stroke, direct injection, Wet cylinder liner, 1500rpm
Constant Output (KW) 336 403 448 560 664 880
Standby Output (KW) 369 448 503 616 731 970
Aspiration Turbocharged and Aftercooled
Bore (mm) x Stroke (mm) 159x159
Cubic Capacity (Liters) 19 38
Piston Speed (m/s) 7.9
Compression Ratio 14.5:1 13.9:1
Cooling System Volume (L) 91 196 202
Max. Water Temperature 100°C
Speed characteristics The speed stability bandwidth <+0.25%. The steady governing rate <1%
Fuel Consumption <215g/kW.h
Lube Consumption (prime) <1.36g/kW.h
Radiated Heat to Ambient (KWm) 50 58 64 96 101 125
Heat Rejection to coolant (KWm) 206 247 240 389 407 539
Heat Rejection to Exhaust (KWm) 239 263 319 540 511 544
Fan Cooling Air Flow (m3/h) 29448 35280 103957 109530
Intake Air Flow (l/s) 432 486 532 802 850 1140
Exhaust Gas Flow (m3/h) 4298 4842 5162 8071 8632 10983
Exhaust Temperature (°C) 524 528 538 541 499
Exhaust Back Pressure 10kPA(Maximum) 6.7kPA(Max)
ALTERNATOR MODEL
SLG314F
SLG354C
SLG354D
SLG404D
SLG404E
SLG404G
Continuous Output (KW/KVA) 304/380 360/450 400/500 500/625 600/750 800/1000
Power Efficiency 92.6% 93.8% 94.10% 94.9% 93.70% 94.7%
Voltage Regulation +-1.0% with 4% engine governing +-0.5% with 4% engine governing
Waveform Distortion No load < 1.5% and non-distorting balanced linear load <5%
THF/TIF <2% / <50
Fan Cooling Air Flow (l/s) 486 1035 1614
DIMENSIONS AND WEIGHTS
Genet Cont. MODEL C300 C360 C400 C500 C600 C800
Length: mm 3750 3670 3670 3800 4300 4670
Width: mm 1220 1220 1220 1520 1600 1750
Height: mm 1900 1900 1900 2250 2250 2250
Net Weight: kg 4200 4350 4800 8600 8950 9250
 


 

CUMMINS RANGE OF SOUND-PROOF GENERATOR SETS C20/S-C500/S

SOUNDPROOF GENSET CHARACTERISTICS
HIGHLY CORROSION RESISTANT CONSTRUCTION
* Body made from special treated steel sheet.
* Stainless steel or cast aluminium locks and hinges.
* Zing plated or stainless steel fasteners.
* 2.5mm thick Sheet treated by grit blast Sa 2½
* Two pack of epoxy paint system.
EXCELLENT ACCESS FOR MAINTENANCE
SECURITY AND SAFETY
* Full length extra wide doors on each side. * Control panel viewing window to easily view status of generating set.
* Doors top hung and supported by gas struts. * Emergency stop button mounted externally.
* Top hinged doors provide a shelter when open. * Cooling fan and battery charging alternator fully guarded.
* Lube oil and cooling water drains piped to exterior of the canopy. * Exhaust silencing system totally enclosed for operator safety.
DIMENSIONS AND WEIGHTS
Sound-proof Genset Rating Power 400V/50HZ Length: mm Width: mm Height: mm Net Weight: kg
Cont. Model kW kVA
C20/S 20 25 1900 1000 1460 980
C30/S 30 37.5 2100 1000 1460 1175
C45/S 45 56 2770 1100 1460 1340
C68/S 68 85 3000 1100 1850 1650
C77/S 77 96 3000 1100 1850 1650
C91/S 91 104 3000 1100 1850 1650
C105/S 105 131 3300 1150 2160 1750
C140/S 140 175 3300 1150 2160 2000
C160/S 160 200 4000 1530 1850 2950
C200/S 200 250 4050 1530 2450 3600
C250/S 250 313 4050 1530 2450 3800
C280/S 280 350 4050 1850 2450 3950
C300/S 300 375 4250 1850 2550 4600
C360/S 360 450 4250 1850 2550 4850
C400/S 400 600 4300 2000 2650 5300
C500/S 500 625 4300 2200 2850 5600